Security Vulnerabilities
- CVEs Published In March 2020
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to bypass access restriction and to stop the network functions or execute malware via a specially crafted packet.
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows an attacker on the same network segment to stop the network functions or execute malware via a specially crafted packet.
Resource Management Errors vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
Null Pointer Dereference vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.
A system command injection vulnerability in the FortiAP-S/W2 6.2.1, 6.2.0, 6.0.5 and below, FortiAP 6.0.5 and below and FortiAP-U below 6.0.0 under CLI admin console may allow unauthorized administrators to run arbitrary system level commands via specially crafted ifconfig commands.
An Insufficient Verification of Data Authenticity vulnerability in FortiManager 6.2.1, 6.2.0, 6.0.6 and below may allow an unauthenticated attacker to perform a Cross-Site WebSocket Hijacking (CSWSH) attack.
An improper input validation vulnerability in FortiOS 6.2.1, 6.2.0, 6.0.8 and below until 5.4.0 under admin webUI may allow an attacker to perform an URL redirect attack via a specifically crafted request to the admin initial password change webpage.
An Unsafe Search Path vulnerability in FortiClient EMS online installer 6.2.1 and below may allow a local attacker with control over the directory in which FortiClientEMSOnlineInstaller.exe resides to execute arbitrary code on the system via uploading malicious Filter Library DLL files in that directory.