Security Vulnerabilities
- CVEs Published In December 2025
Directory traversal vulnerability in SOLIDserver IPAM v8.2.3. This vulnerability allows an authenticated user with administrator privileges to list directories other than those to which the have authorized access using the 'directory' parameter in '/mod/ajax.php?action=sections/list/list'.For examplem setting the 'directory' parameter to '/' displays files outside the 'LOCAL:///' folder.
Reflected Cross-Site Scripting (XSS) in IDI Eikon's Governalia. The vulnerability allows an attacker to execute JavaScript code in the victim's browser when a malicious URL with the 'q' parameter in '/search' is sent to them. This vulnerability can be exploited to steal sensitive information such as session cookies or to perform actions on behalf of the victim.
Unauthorized access vulnerability in TCMAN GIM v11 version 20250304. This vulnerability allows an unauthenticated attacker to determine whether a user exists on the system by using the 'pda:userId' and 'pda:newPassword' parameters with 'soapaction UnlockUser’ in '/WS/PDAWebService.asmx'.
Out-of-bounds read vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'DownloadFile' function converts a parameter to an integer using 'atoi()' and then uses it as an index in the 'FilesDownload' array with '(&FilesDownload)[iVar2]'. If the parameter is too large, it will access memory beyond the limits.
Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using 'system()'. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application.
Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.
Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges.
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without checking the length. An attacker can provide an excessively long value for the 'meter' parameter that exceeds the 64-byte buffer size.