The elasticsearch-operator does not validate the namespace where kibana logging resource is created and due to that it is possible to replace the original openshift-logging console link (kibana console) to different one, created based on the new CR for the new kibana resource. This could lead to an arbitrary URL redirection or the openshift-logging console link damage. This flaw affects elasticsearch-operator-container versions before 4.7.
An incomplete fix for CVE-2020-12662 was shipped for Unbound in Red Hat Enterprise Linux 7, as part of erratum RHSA-2020:2414. Vulnerable versions of Unbound could still amplify an incoming query into a large number of queries directed to a target, even with a lower amplification ratio compared to versions of Unbound that shipped before the mentioned erratum. This issue is about the incomplete fix for CVE-2020-12662, and it does not affect upstream versions of Unbound.
A divide by zero issue was found to occur in libvncserver-0.9.12. A malicious client could use this flaw to send a specially crafted message that, when processed by the VNC server, would lead to a floating point exception, resulting in a denial of service.
A flaw was discovered in WildFly before 21.0.0.Final where, Resource adapter logs plain text JMS password at warning level on connection error, inserting sensitive information in the log file.
An information-disclosure flaw was found in the way that gluster-block before 0.5.1 logs the output from gluster-block CLI operations. This includes recording passwords to the cmd_history.log file which is world-readable. This flaw allows local users to obtain sensitive information by reading the log file. The highest threat from this vulnerability is to data confidentiality.
An information-disclosure flaw was found in the way Heketi before 10.1.0 logs sensitive information. This flaw allows an attacker with local access to the Heketi server to read potentially sensitive information such as gluster-block passwords.
A flaw was found in the Cephx authentication protocol in versions before 15.2.6 and before 14.2.14, where it does not verify Ceph clients correctly and is then vulnerable to replay attacks in Nautilus. This flaw allows an attacker with access to the Ceph cluster network to authenticate with the Ceph service via a packet sniffer and perform actions allowed by the Ceph service. This issue is a reintroduction of CVE-2018-1128, affecting the msgr2 protocol. The msgr 2 protocol is used for all communication except older clients that do not support the msgr2 protocol. The msgr1 protocol is not affected. The highest threat from this vulnerability is to confidentiality, integrity, and system availability.
A flaw was found in rhacm versions before 2.0.5 and before 2.1.0. Two internal service APIs were incorrectly provisioned using a test certificate from the source repository. This would result in all installations using the same certificates. If an attacker could observe network traffic internal to a cluster, they could use the private key to decode API requests that should be protected by TLS sessions, potentially obtaining information they would not otherwise be able to. These certificates are not used for service authentication, so no opportunity for impersonation or active MITM attacks were made possible.
It was found that Keycloak before version 12.0.0 would permit a user with only view-profile role to manage the resources in the new account console, allowing access and modification of data the user was not intended to have.
A flaw in ICMP packets in the Linux kernel may allow an attacker to quickly scan open UDP ports. This flaw allows an off-path remote attacker to effectively bypass source port UDP randomization. Software that relies on UDP source port randomization are indirectly affected as well on the Linux Based Products (RUGGEDCOM RM1224: All versions between v5.0 and v6.4, SCALANCE M-800: All versions between v5.0 and v6.4, SCALANCE S615: All versions between v5.0 and v6.4, SCALANCE SC-600: All versions prior to v2.1.3, SCALANCE W1750D: v8.3.0.1, v8.6.0, and v8.7.0, SIMATIC Cloud Connect 7: All versions, SIMATIC MV500 Family: All versions, SIMATIC NET CP 1243-1 (incl. SIPLUS variants): Versions 3.1.39 and later, SIMATIC NET CP 1243-7 LTE EU: Version