A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the associated user is deleted or disabled or their permissions are modified. This could allow an authenticated attacker to continue performing malicious actions even after their user account has been disabled.
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly sanitize user provided paths for SFTP-based file up- and downloads. This could allow an authenticated remote attacker to manipulate arbitrary files on the filesystem and achieve arbitrary code execution on the device.
A vulnerability has been identified in Spectrum Power 7 (All versions < V24Q3). The affected product contains several root-owned SUID binaries that could allow an authenticated local attacker to escalate privileges.
A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). The user accounts tab of affected devices is vulnerable to stored cross-site scripting (XSS) attacks.
This could allow an authenticated remote attacker to inject arbitrary JavaScript code that is later executed by another authenticated victim user with potential higher privileges than the attacker.
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not authenticate GET requests that execute specific commands (such as `ping`) on operating system level.
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices allows to write arbitrary files to the web server's DocumentRoot directory.
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges.
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
In the Linux kernel, the following vulnerability has been resolved:
drm/amd/display: Fix index out of bounds in degamma hardware format translation
Fixes index out of bounds issue in
`cm_helper_translate_curve_to_degamma_hw_format` function. The issue
could occur when the index 'i' exceeds the number of transfer function
points (TRANSFER_FUNC_POINTS).
The fix adds a check to ensure 'i' is within bounds before accessing the
transfer function points. If 'i' is out of bounds the function returns
false to indicate an error.
Reported by smatch:
drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:594 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.red' 1025 <= s32max
drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:595 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.green' 1025 <= s32max
drivers/gpu/drm/amd/amdgpu/../display/dc/dcn10/dcn10_cm_common.c:596 cm_helper_translate_curve_to_degamma_hw_format() error: buffer overflow 'output_tf->tf_pts.blue' 1025 <= s32max