Vulnerabilities
Vulnerable Software
Siemens:  Security Vulnerabilities
Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again.
CVSS Score
5.1
EPSS Score
0.01
Published
2023-11-14
A vulnerability has been identified in COMOS (All versions < V10.4.4). Caching system in the affected application leaks sensitive information such as user and project information in cleartext via UDP.
CVSS Score
3.5
EPSS Score
0.003
Published
2023-11-14
A vulnerability has been identified in COMOS (All versions < V10.4.4). Ptmcast executable used for testing cache validation service in affected application is vulnerable to Structured Exception Handler (SEH) based buffer overflow. This could allow an attacker to execute arbitrary code on the target system or cause denial of service condition.
CVSS Score
9.6
EPSS Score
0.009
Published
2023-11-14
A vulnerability has been identified in COMOS (All versions). The affected application lacks proper access controls in SMB shares. This could allow an attacker to access files that the user should not have access to.
CVSS Score
9.6
EPSS Score
0.005
Published
2023-11-14
CVE-2023-44487
Known exploited
The HTTP/2 protocol allows a denial of service (server resource consumption) because request cancellation can reset many streams quickly, as exploited in the wild in August through October 2023.
CVSS Score
7.5
EPSS Score
1.0
Published
2023-10-10
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a type confusion vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21268)
CVSS Score
7.8
EPSS Score
0.002
Published
2023-10-10
A vulnerability has been identified in SICAM PAS/PQS (All versions >= V8.00 < V8.20). The affected application is installed with specific files and folders with insecure permissions. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges to `NT AUTHORITY/SYSTEM`.
CVSS Score
7.8
EPSS Score
0.002
Published
2023-10-10
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.262), Parasolid V35.1 (All versions < V35.1.250), Parasolid V36.0 (All versions < V36.0.169), Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a stack overflow vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21290)
CVSS Score
7.8
EPSS Score
0.002
Published
2023-10-10
A vulnerability has been identified in SICAM PAS/PQS (All versions >= V8.00 < V8.22). The affected application is installed with specific files and folders with insecure permissions. This could allow an authenticated local attacker to read and modify configuration data in the context of the application process.
CVSS Score
6.6
EPSS Score
0.001
Published
2023-10-10
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11). The web server of affected devices fails to properly sanitize user input for the /sicweb-ajax/tmproot/ endpoint. This could allow an authenticated remote attacker to traverse directories on the system and download arbitrary files. By exploring active session IDs, the vulnerability could potentially be leveraged to escalate privileges to the administrator role.
CVSS Score
7.5
EPSS Score
0.007
Published
2023-10-10


Contact Us

Shodan ® - All rights reserved