A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition.
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users' sessions.
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
A vulnerability has been identified in Opcenter Quality V13.1 (All versions < V13.1.20220624), Opcenter Quality V13.2 (All versions < V13.2.20220624). The affected applications do not properly validate login information during authentication. This could lead to denial of service condition for existing users or allow unauthenticated remote attackers to successfully login without credentials.
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing PCB files. An attacker could leverage this vulnerability to execute code in the context of the current process. (FG-VD-22-037, FG-VD-22-059)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-038)
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-039)
A vulnerability has been identified in SIMATIC eaSie Core Package (All versions < V22.00). The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow an remote attacker to trigger a denial of service of the affected system.