Vulnerability Details CVE-2025-25249
A heap-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2.0 through 7.2.11, FortiOS 7.0.0 through 7.0.17, FortiOS 6.4 all versions, FortiSwitchManager 7.2.0 through 7.2.6, FortiSwitchManager 7.0.0 through 7.0.5 allows attacker to execute unauthorized code or commands via specially crafted packets
Exploit prediction scoring system (EPSS) score
EPSS Score 0.024
EPSS Ranking 83.3%
CVSS Severity
CVSS v3 Score 8.1
Proposed Action
Fortinet FortiOS, FortiSwitchManager, and FortiSASE contain a heap-based buffer overflow vulnerability that allows an attacker to execute unauthorized code or commands via specially crafted packets.
Ransomware Campaign
Unknown
Products affected by CVE-2025-25249
-
cpe:2.3:a:fortinet:fortisase:25.1.39
-
cpe:2.3:a:fortinet:fortisase:25.1.51
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.0.0
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.0.1
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.0.2
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.0.3
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.0.4
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.0.5
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.2.0
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.2.1
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.2.2
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.2.3
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.2.4
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.2.5
-
cpe:2.3:a:fortinet:fortiswitchmanager:7.2.6
-
cpe:2.3:h:siemens:ruggedcom_ape1808:-
-
cpe:2.3:o:fortinet:fortios:6.4.0
-
cpe:2.3:o:fortinet:fortios:6.4.1
-
cpe:2.3:o:fortinet:fortios:6.4.10
-
cpe:2.3:o:fortinet:fortios:6.4.11
-
cpe:2.3:o:fortinet:fortios:6.4.12
-
cpe:2.3:o:fortinet:fortios:6.4.13
-
cpe:2.3:o:fortinet:fortios:6.4.14
-
cpe:2.3:o:fortinet:fortios:6.4.15
-
cpe:2.3:o:fortinet:fortios:6.4.16
-
cpe:2.3:o:fortinet:fortios:6.4.17
-
cpe:2.3:o:fortinet:fortios:6.4.2
-
cpe:2.3:o:fortinet:fortios:6.4.3
-
cpe:2.3:o:fortinet:fortios:6.4.4
-
cpe:2.3:o:fortinet:fortios:6.4.5
-
cpe:2.3:o:fortinet:fortios:6.4.6
-
cpe:2.3:o:fortinet:fortios:6.4.7
-
cpe:2.3:o:fortinet:fortios:6.4.8
-
cpe:2.3:o:fortinet:fortios:6.4.9
-
cpe:2.3:o:fortinet:fortios:7.0.0
-
cpe:2.3:o:fortinet:fortios:7.0.1
-
cpe:2.3:o:fortinet:fortios:7.0.10
-
cpe:2.3:o:fortinet:fortios:7.0.11
-
cpe:2.3:o:fortinet:fortios:7.0.12
-
cpe:2.3:o:fortinet:fortios:7.0.13
-
cpe:2.3:o:fortinet:fortios:7.0.14
-
cpe:2.3:o:fortinet:fortios:7.0.15
-
cpe:2.3:o:fortinet:fortios:7.0.16
-
cpe:2.3:o:fortinet:fortios:7.0.17
-
cpe:2.3:o:fortinet:fortios:7.0.2
-
cpe:2.3:o:fortinet:fortios:7.0.3
-
cpe:2.3:o:fortinet:fortios:7.0.4
-
cpe:2.3:o:fortinet:fortios:7.0.5
-
cpe:2.3:o:fortinet:fortios:7.0.6
-
cpe:2.3:o:fortinet:fortios:7.0.7
-
cpe:2.3:o:fortinet:fortios:7.0.8
-
cpe:2.3:o:fortinet:fortios:7.0.9
-
cpe:2.3:o:fortinet:fortios:7.2.0
-
cpe:2.3:o:fortinet:fortios:7.2.1
-
cpe:2.3:o:fortinet:fortios:7.2.10
-
cpe:2.3:o:fortinet:fortios:7.2.11
-
cpe:2.3:o:fortinet:fortios:7.2.2
-
cpe:2.3:o:fortinet:fortios:7.2.3
-
cpe:2.3:o:fortinet:fortios:7.2.4
-
cpe:2.3:o:fortinet:fortios:7.2.5
-
cpe:2.3:o:fortinet:fortios:7.2.6
-
cpe:2.3:o:fortinet:fortios:7.2.7
-
cpe:2.3:o:fortinet:fortios:7.2.8
-
cpe:2.3:o:fortinet:fortios:7.2.9
-
cpe:2.3:o:fortinet:fortios:7.4.0
-
cpe:2.3:o:fortinet:fortios:7.4.1
-
cpe:2.3:o:fortinet:fortios:7.4.2
-
cpe:2.3:o:fortinet:fortios:7.4.3
-
cpe:2.3:o:fortinet:fortios:7.4.4
-
cpe:2.3:o:fortinet:fortios:7.4.5
-
cpe:2.3:o:fortinet:fortios:7.4.6
-
cpe:2.3:o:fortinet:fortios:7.4.7
-
cpe:2.3:o:fortinet:fortios:7.4.8
-
cpe:2.3:o:fortinet:fortios:7.6.0
-
cpe:2.3:o:fortinet:fortios:7.6.1
-
cpe:2.3:o:fortinet:fortios:7.6.2
-
cpe:2.3:o:fortinet:fortios:7.6.3
-
cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-