Tenda:  >> Ac7 Firmware  >> 1.0  Security Vulnerabilities
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.
CVSS Score
5.1
EPSS Score
0.0
Published
2026-02-03
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.
CVSS Score
8.2
EPSS Score
0.0
Published
2026-02-03
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser context.
CVSS Score
5.1
EPSS Score
0.0
Published
2026-02-03
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack appropriate Cache-Control directives, which may permit web browsers to cache pages containing these credentials and enable subsequent disclosure to an attacker with access to the client system or browser profile.
CVSS Score
6.8
EPSS Score
0.0
Published
2026-02-03
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVSS Score
8.7
EPSS Score
0.012
Published
2025-03-03
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
CVSS Score
9.8
EPSS Score
0.002
Published
2023-07-14
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
CVSS Score
9.8
EPSS Score
0.002
Published
2023-07-14
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
CVSS Score
9.8
EPSS Score
0.002
Published
2023-07-14
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.
CVSS Score
7.5
EPSS Score
0.003
Published
2019-04-25
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.